Contact Us

Operations · 3 min · 747 words

Logging humidity for under forty dollars

The single highest-return measurement in a packaging operation, and you do not need a building management system to take it.

Hattie BrunGrading lead · April 11, 2025
OperationsOperationsStorageMeasurement
Used flat-packed corrugated stacked on pallets inside an older brick warehouse
OperationsIntake waiting on the grading lanes. Dry, indoors, on pallets — which is why this lot will grade well.

While it is fresh

Quote the thing you just read about

Mention the post in the message field and we will answer in the same terms it was written in.

A working address — this is where the quote goes.
US or Canada only — 10 digits, in the shape (614) 000-0000. We format it as you type
Two-letter code or full name (OH or Ohio).
US ZIP (43228 or 43228-1234) or Canadian code (M5V 2T6)
Whole units, at least 1.
Pick a suggestion or describe it.
Pick a suggestion or describe it.
Optional — we will recommend one.

No phone calls — we are an email-first yard. Your details go to our sales desk only, never to a list broker.

Board strength falls about 30% between 50% and 85% relative humidity. Almost no warehouse we visit knows its own humidity profile, and almost all of them are surprised by it once they measure.

What to buy

A battery-powered data logger with a display costs between $18 and $40 and records temperature and relative humidity every few minutes for months. You need three: one where empties are stored, one at the dock door, one in the middle of the building. That is the entire capital expenditure.

  • Display matters more than connectivity. People glance at a number on a wall; nobody logs into a dashboard to check a warehouse.
  • Put one within six feet of the empty-box stack, at stack height, not at head height.
  • Record for a full month before drawing conclusions. A week tells you about the weather, not the building.
  • Write the readings on the intake sheet if you are selling boxes — it is genuinely worth money to you.
What we measured across eleven customer sites, March 2025
Location in buildingMean RHPeak RHHours above 70% RH
Within 15 ft of dock door68%91%214 of 720
Against exterior wall64%84%138 of 720
Building centre54%71%11 of 720
Mezzanine / upper level49%66%0 of 720

Look at the first and last rows. The same building, measured in the same month, has a 19-point spread in mean humidity. Where a stack sits inside a warehouse matters more than almost any other storage decision, and moving it is free.

The finding that pays for the loggers in a weekIf your empty-box storage is within fifteen feet of a dock door, move it to the building centre. At eleven sites we measured, that change alone would have raised the grade — and therefore our buy-back price — on roughly a third of the stock.

What to do with the numbers

  1. Above 70% RH for sustained periods: move the stack, or add airflow. Fans are cheaper than dehumidification and often sufficient.
  2. Rapid swings rather than a high mean: the problem is a door or a vent, not the building. Swings cause condensation, which is worse than a steady high reading.
  3. Above 80%: stop storing board there at all. Nothing else you do will compensate.
  4. Below 60% steady: you are fine, and you can stop thinking about it.

Why we care

Selfishly: board stored properly is board we can resell, which means we pay more for it. Less selfishly, the 24% of our unsellable intake that was stored on concrete and the 11% stored against an exterior wall represent about 230 tons a year of perfectly good board that was destroyed by where it was standing. A $40 logger is the cheapest intervention available in this entire market.

Reading the log without over-interpreting it

A month of data from three loggers will tell you four things and tempt you to conclude eight. The four things it genuinely supports:

  • The mean humidity at each location, which determines steady-state board strength.
  • The peak, which tells you whether you ever enter the danger zone.
  • The hours above 70%, which is the number that correlates with downgrade in our intake data.
  • The swing amplitude, which predicts condensation risk — a bigger problem than a high steady reading.

What it does not tell you is causation. A high reading near a dock door might be the door, or a nearby wash-down area, or a roof leak twenty feet away. Move the logger before you spend money on dehumidification.

What we do with our own logs

Our grading floor, 2025 full year
MeasureGrading floorIntake bay (unheated)Outbound stack
Mean RH52%61%50%
Peak RH71%88%66%
Hours above 70%386120
Action takenNoneProtocol appliesNone

The intake bay is deliberately unheated and deliberately humid, because its job is to let cold pallets acclimatise without condensing rather than to store board. Nothing sits there longer than overnight. The 612 hours above 70% would be alarming in a storage area and are irrelevant in a transit one, which is the kind of distinction a logger alone will not make for you.

The cheapest useful habit

Write the reading on the intake sheet. Thirty seconds, every delivery. Within a quarter you will know whether your board arrives dry, and within a year you will be able to tell a supplier why their stock grades the way it does. We started doing this in 2014 and it is the origin of nearly every storage recommendation on this website.

end of post

Used flat-packed corrugated stacked on pallets inside an older brick warehouse

Written from the floor

Everything on this blog came out of a question somebody asked twice

Forty-three posts, five writers, no gated whitepapers. If a post contains a number, the method behind it is either in the post or linked from it.

The whole archive

Next step

Reading is cheaper than a wrong order.

If anything above applies to your operation and you want it checked against real stock, the form takes a minute.

Contact Us