Operations · 3 min · 747 words
Logging humidity for under forty dollars
The single highest-return measurement in a packaging operation, and you do not need a building management system to take it.

While it is fresh
Quote the thing you just read about
Mention the post in the message field and we will answer in the same terms it was written in.
Board strength falls about 30% between 50% and 85% relative humidity. Almost no warehouse we visit knows its own humidity profile, and almost all of them are surprised by it once they measure.
What to buy
A battery-powered data logger with a display costs between $18 and $40 and records temperature and relative humidity every few minutes for months. You need three: one where empties are stored, one at the dock door, one in the middle of the building. That is the entire capital expenditure.
- Display matters more than connectivity. People glance at a number on a wall; nobody logs into a dashboard to check a warehouse.
- Put one within six feet of the empty-box stack, at stack height, not at head height.
- Record for a full month before drawing conclusions. A week tells you about the weather, not the building.
- Write the readings on the intake sheet if you are selling boxes — it is genuinely worth money to you.
| Location in building | Mean RH | Peak RH | Hours above 70% RH |
|---|---|---|---|
| Within 15 ft of dock door | 68% | 91% | 214 of 720 |
| Against exterior wall | 64% | 84% | 138 of 720 |
| Building centre | 54% | 71% | 11 of 720 |
| Mezzanine / upper level | 49% | 66% | 0 of 720 |
Look at the first and last rows. The same building, measured in the same month, has a 19-point spread in mean humidity. Where a stack sits inside a warehouse matters more than almost any other storage decision, and moving it is free.
What to do with the numbers
- Above 70% RH for sustained periods: move the stack, or add airflow. Fans are cheaper than dehumidification and often sufficient.
- Rapid swings rather than a high mean: the problem is a door or a vent, not the building. Swings cause condensation, which is worse than a steady high reading.
- Above 80%: stop storing board there at all. Nothing else you do will compensate.
- Below 60% steady: you are fine, and you can stop thinking about it.
Why we care
Selfishly: board stored properly is board we can resell, which means we pay more for it. Less selfishly, the 24% of our unsellable intake that was stored on concrete and the 11% stored against an exterior wall represent about 230 tons a year of perfectly good board that was destroyed by where it was standing. A $40 logger is the cheapest intervention available in this entire market.
Reading the log without over-interpreting it
A month of data from three loggers will tell you four things and tempt you to conclude eight. The four things it genuinely supports:
- The mean humidity at each location, which determines steady-state board strength.
- The peak, which tells you whether you ever enter the danger zone.
- The hours above 70%, which is the number that correlates with downgrade in our intake data.
- The swing amplitude, which predicts condensation risk — a bigger problem than a high steady reading.
What it does not tell you is causation. A high reading near a dock door might be the door, or a nearby wash-down area, or a roof leak twenty feet away. Move the logger before you spend money on dehumidification.
What we do with our own logs
| Measure | Grading floor | Intake bay (unheated) | Outbound stack |
|---|---|---|---|
| Mean RH | 52% | 61% | 50% |
| Peak RH | 71% | 88% | 66% |
| Hours above 70% | 38 | 612 | 0 |
| Action taken | None | Protocol applies | None |
The intake bay is deliberately unheated and deliberately humid, because its job is to let cold pallets acclimatise without condensing rather than to store board. Nothing sits there longer than overnight. The 612 hours above 70% would be alarming in a storage area and are irrelevant in a transit one, which is the kind of distinction a logger alone will not make for you.
The cheapest useful habit
Write the reading on the intake sheet. Thirty seconds, every delivery. Within a quarter you will know whether your board arrives dry, and within a year you will be able to tell a supplier why their stock grades the way it does. We started doing this in 2014 and it is the origin of nearly every storage recommendation on this website.
end of post